Launch offer — valid today only

📄 Digital book in PDF · read it on your phone or print it

Data Cabling in Drawings: Survey, Terminate and Test Every Job in the Same Order One Topic on Every Page

Containment, separation from mains, T568A and T568B, keystones, patch panels, the 19-inch rack, testing and fault finding. Every topic has its own page: the drawing first, then what you need to remember. 67 illustrated pages.

GET THE BOOK + 2 FREE BOOKS

🔒 Secure checkout · PDF by email · 30-day guarantee

Every topic, its own pageOne topic, one page, one drawing
67 illustrated pages67 illustrated pages in 9 parts
Up-to-date sourcesChecked against BS EN 50173, BS EN 50174 and BS 7671
PDF by emailFormat

Look Inside the Book

Every page has one big drawing and a box with the distances, colours and steps you need to know:

Campus, building and floor distributors, backbone, horizontal, outlet: one drawing, the spec's own words.
Campus, building and floor distributors, backbone, horizontal, outlet: one drawing, the spec's own words.
4 colour pairs, 4 different twist rates: the drawing that explains crosstalk
4 colour pairs, 4 different twist rates: the drawing that explains crosstalk
8 survey steps: cabinet, outlets, routes, voids, fire walls, power, PoE, access and asbestos
8 survey steps: cabinet, outlets, routes, voids, fire walls, power, PoE, access and asbestos
Lighting drivers, motors, lifts, transformers: BS EN 50174-2 sets minimum distances
Lighting drivers, motors, lifts, transformers: BS EN 50174-2 sets minimum distances
T568A vs T568B pin by pin: only the orange and green pairs change places.
T568A vs T568B pin by pin: only the orange and green pairs change places.
19 in = 482.6 mm wide · 1U = 44.45 mm · depth depends on the maker
19 in = 482.6 mm wide · 1U = 44.45 mm · depth depends on the maker
Verifier, qualifier, certifier: only the third measures against Class limits and backs a warranty.
Verifier, qualifier, certifier: only the third measures against Class limits and backs a warranty.
Label, set-up, wire map, length, performance, one end, the other end
Label, set-up, wire map, length, performance, one end, the other end

Swipe to see more →

These are real pages from the book. The table of contents is the full one: 9 parts and 63 topics.

The Problem Isn't You. It's How It Was Explained.

You're walking round a new office fit-out with the client, notepad in hand, and you've got twenty minutes to work out what this job needs.

Back in the van you realise you never asked about the fire walls or the asbestos register. It was all in the guidance somewhere, spread over pages of paragraphs, and on site nothing told you what came next.

8 survey steps: cabinet, outlets, routes, voids, fire walls, power, PoE, access and asbestos

In the book, the site survey is one page: eight numbered steps in a drawing, always in the same order: cabinet, outlets, routes, voids, fire walls, power and PoE, access, and asbestos.

The same goes for the 90 + 10 rule, Band I and Band II, T568A and T568B, the 19-inch rack and the wire map: each one has its own page.

On the next walk-round you ask the right questions in the right order and leave knowing what the job needs, without going back to the manual.

COMPARE FOR YOURSELF

The Same Topic, Two Ways to Learn It

THIS
  • The manual: line after line
  • Pairs, twists and crosstalk explained in words alone
  • You turn up on site still unsure
A balanced twisted-pair cable comprises four pairs of insulated solid copper conductors, each pair being identified by a base colour (blue, orange, green or brown) and a corresponding white-striped mate. The conductors of each pair are helically twisted at a lay length which differs deliberately from that of the adjacent pairs, in order that electromagnetic coupling between pairs is reduced and near-end and far-end crosstalk remain within the limits applicable to the specified category of performance, subject to the conditions of installation described elsewhere.
FOR THIS
  • The cable cut open in one drawing
  • Pair colours and twist rates in a box
  • You see it and it makes sense
4 colour pairs, 4 different twist rates: the drawing that explains crosstalk
CONTENTS

Take a Look at the 9 Parts and 63 Topics

The system end to end, cables and components, planning and routes, separation and fire, termination, the comms cabinet, testing, fault finding and on-site paperwork: 67 pages, all illustrated.

IThe System, End to End · pp. 5-11
  1. The Whole System on One Page
  2. Permanent Link vs Channel
  3. The 90 + 10 Rule, Worked Out
  4. Categories and Classes Decoded
  5. What a Structured System Is For
  6. Data in New Homes and Refurbs
  7. Who Does What on a Job
IICables and Components · pp. 12-18
  1. Inside a Twisted-Pair Cable
  2. U/UTP, F/UTP, S/FTP: Reading the Name
  3. Solid vs Stranded
  4. Fire Ratings on the Drum: Euroclasses
  5. Outlets, Keystones and Faceplates
  6. Patch Panels: Loaded vs Unloaded
  7. Patch Cords and Why They Matter
IIIPlanning and Routes · pp. 19-25
  1. The Site Survey in Order
  2. Measuring a Route Properly
  3. Choosing the Containment
  4. Fill: How Many Cables Fit
  5. Bend Radius Without Guesswork
  6. Pulling Without Damage
  7. Bundles, Ties and PoE Heat
IVSeparation, Fire and Safety · pp. 26-32
  1. Band I and Band II: Why Data and Mains Don't Share
  2. Separation Distances on Parallel Runs
  3. Crossing Power Cables
  4. Other Sources of Interference
  5. Cables Must Not Collapse in a Fire
  6. Fire Stopping Every Penetration
  7. Earthing and Bonding at the Cabinet
VTermination, Step by Step · pp. 33-41
  1. T568A and T568B in Colour
  2. Stripping the Jacket Without Nicking
  3. Keeping the Twist: 13 mm Maximum
  4. Punching Down a Keystone in Order
  5. Terminating a Patch Panel
  6. Tool-Less Modules
  7. Crimping an RJ45 Plug
  8. Terminating Screened Cable
  9. Service Loops and Slack
VIThe Comms Cabinet · pp. 42-47
  1. Reading a 19-Inch Rack
  2. Laying Out the Rack
  3. Cable Management Inside the Cabinet
  4. Power, Heat and Ventilation
  5. Labelling That Anyone Can Follow
  6. Patching Neatly
VIITesting and Certification · pp. 48-54
  1. Verifier, Qualifier, Certifier
  2. Before You Test: Set-Up in Order
  3. Reading the Wire Map
  4. Length, Delay and Skew
  5. Insertion Loss and Return Loss
  6. NEXT, PS NEXT and ACR-F
  7. Pass, Fail and the Asterisk
VIIIFault Finding · pp. 55-61
  1. Fault Finding in the Same Order
  2. Open Circuit
  3. Short Circuit
  4. Reversed Pair
  5. Crossed Pairs
  6. Split Pair: the Fault a Basic Tester Misses
  7. Failing NEXT or Return Loss With a Good Wire Map
IXOn Site: Paperwork, Handover and Mistakes · pp. 62-67
  1. Site Survey Sheet
  2. Cable Schedule Sheet
  3. Test Record Sheet
  4. Handover Checklist
  5. The Most Frequent Mistakes at a Glance
  6. Quick Reference for the Van

One Page, One Topic, All Clear

Think of it this way:

The tester flags outlet 14, the site manager is stood right behind you, and you need to know where to look first.

You open the fault-finding page and the order is drawn in front of you: label, set-up, wire map, length, performance, one end, then the other.

T568A vs T568B pin by pin: only the orange and green pairs change places.

Same with the 90 + 10 rule, bend radius, separation from mains, punching down a keystone and labelling the rack: each one on its own page.

Data Cabling Illustrated is 9 parts and 63 topics, all drawn, ending with blank site sheets, the most frequent mistakes and a quick reference for the van.

What you see drawn, you don't have to memorize.

What's Inside Data Cabling Illustrated:

Ipp. 5-11

The System, End to End

The whole system on one page, permanent link vs channel, the 90 + 10 rule worked out, categories and classes, new homes and refurbs, who does what on a job.

IIpp. 12-18

Cables and Components

Inside a twisted-pair cable, U/UTP, F/UTP and S/FTP, solid vs stranded, Euroclass fire ratings, outlets and keystones, patch panels and patch cords.

IIIpp. 19-25

Planning and Routes

The site survey in order, measuring a route, choosing the containment, fill, bend radius, pulling without damage, bundles and PoE heat.

IVpp. 26-32

Separation, Fire and Safety

Band I and Band II, separation on parallel runs, crossing power cables, other interference, cables that don't collapse in a fire, fire stopping, earthing and bonding.

Vpp. 33-41

Termination, Step by Step

T568A and T568B in colour, stripping without nicking, the 13 mm untwist limit, keystones, patch panels, tool-less modules, RJ45 plugs, screened cable, service loops.

VIpp. 42-47

The Comms Cabinet

Reading a 19-inch rack, laying it out, cable management, power and ventilation, labelling anyone can follow, neat patching.

VIIpp. 48-54

Testing and Certification

Verifier, qualifier and certifier, set-up before testing, the wire map, length and skew, insertion and return loss, NEXT, pass, fail and the asterisk.

VIIIpp. 55-61

Fault Finding

Fault finding in the same order, open, short, reversed pair, crossed pairs, split pair, and failing NEXT with a good wire map.

IXpp. 62-67

On Site: Paperwork, Handover and Mistakes

Site survey sheet, cable schedule, test record, handover checklist, the most frequent mistakes at a glance and a quick reference for the van.

At the end of the book: Blank site sheets (survey, cable schedule, test record, handover), the most frequent mistakes at a glance and a quick reference for the van.

Plus: 2 Free Books

Fault-Finding Workbook: Test Results to Read

BONUS 1: «Fault-Finding Workbook: Test Results to Read»

Value on its own: US$ 17.90

Practise reading real-looking wire maps and test screens until open, short, split pair and reversed pair are obvious at a glance.

Common Cabling Mistakes: Before & After Cards

BONUS 2: «Common Cabling Mistakes: Before & After Cards»

Value on its own: US$ 14.90

The most frequent installation mistakes drawn side by side with the right way, so you spot them before the tester does.

Data Cabling Illustrated with 2 Free Books

  • Data Cabling Illustrated: 67 illustrated pagesUS$ 63
  • BONUS 1: Fault-Finding Workbook: Test Results to ReadUS$ 17.90
  • BONUS 2: Common Cabling Mistakes: Before & After CardsUS$ 14.90
  • High-resolution PDF to printIncluded
Total value US$ 95.80
YOUR PRICE:
US$ 27
You save US$ 68.80
YES, I WANT DATA CABLING ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

Secure purchaseEncrypted payment30-day guarantee

PDF by email: We email you Data Cabling Illustrated as a PDF, together with the two free books. It's a single payment: no installments, no extra charges.

Who This Book Is For

You're an electrician adding data work

You're an electrician adding data work

Every job now asks for data points. The book gives you the rules that differ from mains work, separation, bend radius, 90 + 10, drawn so you get them right first time.

You've been handed the rack at work

You've been handed the rack at work

The patch panel, the labels and the tester are now your job. Each one is a page, so you can sort the cabinet and read a result without guessing.

You've done cabling for years

You've done cabling for years

You learned it on site from someone else. Here the whole system and the test order sit in one place, to check what you half-remember and keep in the van.

Everything You Get Today

US$ 95.80US$ 27
YES, I WANT DATA CABLING ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.

30DAYS
GUARANTEE

30-Day Guarantee

Try Data Cabling Illustrated for 30 days, bonus books included.

We refund everything if the file won't open, if the book isn't what you see here, if you were charged twice or if the email doesn't arrive. Just email us.

You pay once. No subscriptions.

Frequently Asked Questions

Is it for me if I already do data work on site?

Yes. It doesn't start from zero: it puts the whole system, the key numbers and the testing order in one place, drawn, so you can check what you half-remember.

Where does the content come from?

It's checked against the current editions of the British and European cabling standards: BS EN 50173, BS EN 50174-1 and -2, BS 6701, BS EN 50346 and BS 7671, plus Approved Document R. It's written for UK jobs, not translated from a US book: metric, UK terms, Band I and Band II. All explained in our own words and drawings.

Is it official material?

No. It's an independent illustrated guide. It isn't published, approved or endorsed by BSI, the IET or any standards body, and it doesn't reproduce text or tables from the standards.

Does it replace formal training?

No. It's study and reference material: it doesn't come with a certificate or a qualification. It doesn't replace formal training, manufacturer instructions or the risk assessment on your site.

Are the practice exercises taken from an exam?

No. The test screens and wire maps in the workbook are written for this book. They aren't questions from any exam or certification scheme.

When and how do I get it?

As a PDF by email, to the address you enter at checkout. The 2 free books come with it.

Do I have to pay every month?

No. It's a one-off payment, with no subscription.

Can I have it on paper?

Yes. The PDF prints on A4, so you can print the pages you need and keep them in the van.

How does the refund work?

You have 30 days. We refund everything if the file won't open, if the book isn't what you see on this page, if you were charged twice or if the email doesn't arrive: just email us.

Before You Close This Page

No more rereading without anything sticking.

Outlet 14 fails: you know what to check first, and in what order.

You arrive on site knowing where everything is.

Drawings make studying faster.

The book is right below.

One-time payment: US$ 27 · Guarantee: 30 days · PDF by email

YES, I WANT DATA CABLING ILLUSTRATED FOR US$ 27

📄 This is a digital PDF book sent to your email: nothing is printed or shipped.